<!-- Global site tag (gtag.js) - Google Analytics --> <script async src="https://www.googletagmanager.com/gtag/js?id=UA-139882526-1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'UA-139882526-1'); </script>

Rittal IT Cooling Offers Great Benefits

EMR Associates offers the highest quality cooling systems through Rittal IT Cooling. The benefits of Rittal’s cooling systems are numerous, however, here are just a few benefits your company will experience:

  • Increase Air Inlet Temperatures
  • Higher Equipment Delta T
  • Focus Less on Humidity Control
  • Greater Awareness of Free Cooling
  • Use of Economizers
  • Effects of Contamination
  • Improve Overall Efficiency

Below are some of the systems we currently offer to our customers:

Liquid cooling packages

Liquid Cooling Package LCP Rack CWCooling via high-performance compact impellers. The LCP draws in the air at the sides at the rear of the server enclosures and blows the cooled air back into the front part of the server enclosure at the sides.

Liquid Cooling Package LCP Inline CWBayed climate control designed for siting within a bayed enclosure suite. The hot air is extracted at the rear of the unit, cooled and then expelled forwards to the cold aisle.

Liquid Cooling Package LCP Rack DXRack-based cooling on one to two IT racks. Continuous cooling output adjustment due to the use of an output-controlled compressor in the LCP Rack DX (evaporator) An external condenser is required to operate the unit.

Liquid Cooling Package LCP Inline DXBay-based cooling in conjunction with open/perforated IT racks. Continuous cooling output adjustment due to the use of an output-controlled compressor in the LCP Inline DX (evaporator) An external condenser is required to operate the unit.

Aisle containment

Door and roof components separate hot and cold air in the data centre. Such a separation is pivotal to increasing the efficiency of climate control technology. It may be used as a hot or cold aisle containment.

Roof-mounted cooling units for cooling IT equipment

Active climate control of individual enclosures for heat losses of up to 3 kW. Target temperature-controlled control of the server inlet temperature.

Small Cooling Units

Air duct for side air routing – For cold air supply to hubs with side air intake.

482.6 mm (19″) air duct for horizontal air routing – For a cold air supply to hubs fitted in the rear 482.6 mm (19″) level.

Roof-mounted fans for TS, TS IT, for the office sector – Roof-mounted fan for the office sector with exceptionally low noise level (40 dB) and high volumetric flow (unimpeded air flow 1500 m3/h).

Fan mounting plate for TS 8 – May be retro-fitted in all TS 8 network enclosures from above. The rear section is left free for cable entry. 2 fans as standard. To extend to max. 4/6 fans.

Computer Room Air Conditioner

Room air-conditioning for data centres with a high thermal load.

Computer Room Air Conditioner CRAC CW – Precision climate control unit for cold water operation

Computer Room Air Conditioner CRAC DX – Precision climate control unit for direct evaporation with external air-cooled condenser